$ EZ-EDS Version 3.31.1.20220811 Generated Electronic Data Sheet [File] DescText = "S300 CENT EDS File"; CreateDate = 07-17-2006; CreateTime = 12:00:00; ModDate = 01-15-2024; ModTime = 10:38:25; Revision = 1.6; $ VendName, ProdName are changed [Device] VendCode = 259; VendName = "LS ELECTRIC Co., Ltd."; ProdType = 2; ProdTypeStr = "AC Drive Device"; ProdCode = 7200; $ modified 100 to 7000+10X MajRev = 1; MinRev = 1; ProdName = "S300_CENT"; $ Origin "CENT" Catalog = "S300"; $ "iS7, G100, H100, S100"; $ Catalog List all supported Inverter model names [Device Classification] Class1 = EtherNetIP; $ There is a problem in RSNetWorx with unused Connection Manager connections. $ Connection Manager is not used by, for example, 1756 series, which may $ cause the program to crash. If it happens, you can try to delete the sections $ Params and Connection Manager in this file. [Params] Param1 = 0, $ first field shall equal 0 ,, $ path size,path 0x0000, $ descriptor 0xC7, $ data type : 16-bit Unsigned Integer 2, $ data size in bytes "Output Size", $ name "", $ units "", $ help string 2,32,4, $ min,max,default data values, 0,450,16, ,,,, $ mult,dev,base,offset scaling not used ,,,, $ mult,dev,base,offset link not used 0; $ decimal places not used Param2 = 0, $ first field shall equal 0 ,, $ path size,path 0x0000, $ descriptor 0xC7, $ data type : 16-bit Unsigned Integer 2, $ data size in bytes "Input Size", $ name "", $ units "", $ help string 2,32,4, $ min,max,default data values, 8,454,20, ,,,, $ mult,dev,base,offset scaling not used ,,,, $ mult,dev,base,offset link not used 0; Param3 = 0, $ first field shall equal 0 ,, $ path size,path 0x0000, $ descriptor 0xC6, $ data type : 8-bit Unsigned Char 1, $ data size in bytes "Consumer", $ name "", $ units "", $ help string 20,136,121, $ min,max,default data values *** This must be changed to 20,102,20 when a new release of NetWorx is done. ,,,, $ mult,dev,base,offset scaling not used ,,,, $ mult,dev,base,offset link not used ; Enum3 = 121,"121", 122,"122", 123,"123", 124,"124", 125,"125", 126,"126", 127,"127", 128,"128", $ ; 129,"129", 130,"130", 131,"131", 132,"132", 133,"133", 134,"134", 135,"135", 136,"136", 20,"20", 21,"21", 100,"100", 101,"101"; Param4 = 0, $ first field shall equal 0 ,, $ path size,path 0x0000, $ descriptor 0xC6, $ data type : 8-bit Unsigned Char 1, $ data size in bytes "Producer", $ name "", $ units "", $ help string 70,156,141, $ min,max,default data values ,,,, $ mult,dev,base,offset scaling not used ,,,, $ mult,dev,base,offset link not used ; Enum4 = 141,"141", 142,"142", 143,"143", 144,"144", 145,"145", 146,"146", 147,"147", 148,"148", $ ; 149,"149", 150,"150", 151,"151", 152,"152", 153,"153", 154,"154", 155,"155", 156,"156", 70,"70", 71,"71", 110,"110", 111,"111"; Param5 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD2, $ data type 2, $ Data Size in bytes "CW", $ name "", $ units "Control Word", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param6 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD2, $ data type 2, $ Data Size in bytes "SW", $ name "", $ units "Status Word", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param7 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD2, $ data type : 2, $ Data Size in bytes "Speed Ref(RPM)", $ name "", $ units "Speed Reference(RPM)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param8 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD2, $ data type : 2, $ Data Size in bytes "Speed Ref(Hz)", $ name "", $ units "Speed Reference(Hz)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param9 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD2, $ data type : 2, $ Data Size in bytes "Act Speed(RPM)", $ name "", $ units "Actual Speed(RPM)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param10 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD2, $ data type : 2, $ Data Size in bytes "Act Speed(Hz)", $ name "", $ units "Actual Speed(Hz)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param11 = 0, ,, 0x0000, 0xC7, 2, "OutData", "", "", 0,65535,0, ,,,, ,,,, ; Param21 = 0, ,, 0x0000, 0xC7, 2, "InData", "", "", 0,65535,0, ,,,, ,,,, ; Param30 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC1, $ data type : 1, $ Data Size in bytes "Reserved (1Bit)", $ name "", $ units "Reserved", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param31 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD1, $ data type : 1, $ Data Size in bytes "Reserved (8Bit)", $ name "", $ units "Reserved", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param101 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "RunFwdBit0", $ name "", $ units "Forward Run Command", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param102 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "RunRevBit1", $ name "", $ units "Reverse Run Command", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param103 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "FaultResetBit2", $ name "", $ units "Fault Reset Command", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param104 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "NetCtrlBit5", $ name "", $ units "Not used, set by LCD Control Pannel only", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param105 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "NetReflBit6", $ name "", $ units "Not used, set by LCD Control Pannel only", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param111 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "FaultedBit0", $ name "", $ units "Inverter Error", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param112 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "WarningBit1 ", $ name "", $ units "Not used, Not Supported", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param113 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "Running1(Fwd)Bit2 ", $ name "", $ units "Motor is running Forward", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param114 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "Running2(Rev)Bit3 ", $ name "", $ units "Motor is running Reverse", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param115 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "ReadyBit4 ", $ name "", $ units "Motor is ready to running", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param116 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "CtrlFromBit5 ", $ name "", $ units "Net Run/Stop control ",$ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param117 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "RefFromBit6 ", $ name "", $ units "Net Speed control ", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param118 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "AtReferenceBit7 ", $ name "", $ units "Reach at reference Speed", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param119 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD1, $ Data Type 1, $ Data Size in bytes "DriveState(8Bit)", $ name "", $ units "Current Motor State", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places [Assembly] Assem1 = "Output Data", , 32, $ 16, 0x0001, ,, 16,Param11, 16,Param11, 16,Param11, 16,Param11, 16,Param11, 16,Param11, 16,Param11, 16,Param11, 16,Param11, 16,Param11, 16,Param11, 16,Param11, 16,Param11, 16,Param11, 16,Param11, 16,Param11; Assem2 = "Input Data", , 32, $ 16, 0x0001, ,, 16,Param21, 16,Param21, 16,Param21, 16,Param21, 16,Param21, 16,Param21, 16,Param21, 16,Param21, 16,Param21, 16,Param21, 16,Param21, 16,Param21, 16,Param21, 16,Param21, 16,Param21, 16,Param21; Assem20 = "Basic speed control(RPM) assembly", , 4, 0x0000, ,, 1,Param101, $ Forward Run Command 1,Param30, $ Reserved (1Bit) 1,Param103, $ Fault Reset Command 1,Param30, $ Reserved (1Bit) 1,Param30, $ Reserved (1Bit) 1,Param30, $ Reserved (1Bit) 1,Param30, $ Reserved (1Bit) 1,Param30, $ Reserved (1Bit) 8,Param31, $ Reserved (8Bit) 16,Param7; $ Speed Reference(RPM) Assem21 = "Extended speed control(RPM) assembly", , 4, 0x0000, ,, 1,Param101, $ Forward Run Command 1,Param102, $ Reverse Run Command 1,Param103, $ Fault Reset Command 1,Param30, $ Reserved (1Bit) 1,Param30, $ Reserved (1Bit) 1,Param104, $ Not used, set by LCD Control Pannel only 1,Param105, $ Not used, set by LCD Control Pannel only 1,Param30, $ Reserved (1Bit) 8,Param31, $ Reserved (8Bit) 16,Param7; $ Speed Reference(RPM) Assem70 = "Basic speed status(RPM) assembly", , 4, 0x0000, ,, 1,Param111, $ Inverter Error 1,Param30, $ Reserved (1Bit) 1,Param113, $ Motor is running Forward 1,Param30, $ Reserved (1Bit) 1,Param30, $ Reserved (1Bit) 1,Param30, $ Reserved (1Bit) 1,Param30, $ Reserved (1Bit) 1,Param30, $ Reserved (1Bit) 8,Param31, $ Reserved (8Bit) 16,Param9; $ Actual Speed(RPM) Assem71 = "Extended speed status(RPM) assembly", , 4, 0x0000, ,, 1,Param111, $ Inverter Error 1,Param112, $ Not used, Not Supported 1,Param113, $ Motor is running Forward 1,Param114, $ Motor is running Reverse 1,Param115, $ Motor is ready to running 1,Param116, $ Net Run/Stop control 1,Param117, $ Net Speed control 1,Param118, $ Reach at reference Speed 8,Param119, $ Current Motor State 16,Param9; $ Actual Speed(RPM) Assem100 = "Basic speed control(Hz) assembly", , 4, 0x0000, ,, 1,Param101, $ Forward Run Command 1,Param30, $ Reserved (1Bit) 1,Param103, $ Fault Reset Command 1,Param30, $ Reserved (1Bit) 1,Param30, $ Reserved (1Bit) 1,Param30, $ Reserved (1Bit) 1,Param30, $ Reserved (1Bit) 1,Param30, $ Reserved (1Bit) 8,Param31, $ Reserved (8Bit) 16,Param8; $ Speed Reference(Hz) Assem101 = "Extended speed control(Hz) assembly", , 4, 0x0000, ,, 1,Param101, $ Forward Run Command 1,Param102, $ Reverse Run Command 1,Param103, $ Fault Reset Command 1,Param30, $ Reserved (1Bit) 1,Param30, $ Reserved (1Bit) 1,Param104, $ Not used, set by LCD Control Pannel only 1,Param105, $ Not used, set by LCD Control Pannel only 1,Param30, $ Reserved (1Bit) 8,Param31, $ Reserved (8Bit) 16,Param8; $ Speed Reference(Hz) Assem110 = "Basic speed status(Hz) assembly", , 4, 0x0000, ,, 1,Param111, $ Inverter Error 1,Param30, $ Reserved (1Bit) 1,Param113, $ Motor is running Forward 1,Param30, $ Reserved (1Bit) 1,Param30, $ Reserved (1Bit) 1,Param30, $ Reserved (1Bit) 1,Param30, $ Reserved (1Bit) 1,Param30, $ Reserved (1Bit) 8,Param31, $ Reserved (8Bit) 16,Param10; $ Actual Speed(Hz) Assem111 = "Extended speed status(Hz) assembly", , 4, 0x0000, ,, 1,Param111, $ Inverter Error 1,Param112, $ Not used, Not Supported 1,Param113, $ Motor is running Forward 1,Param114, $ Motor is running Reverse 1,Param115, $ Motor is ready to running 1,Param116, $ Net Run/Stop control 1,Param117, $ Net Speed control 1,Param118, $ Reach at reference Speed 8,Param119, $ Current Motor State 16,Param10; $ Actual Speed(Hz) Assem128 = "Vendor Specific 8words control, Drive parameters", , 16, 0x0000, ,, 16,Param11, 16,Param11, 16,Param11, 16,Param11, 16,Param11, 16,Param11, 16,Param11, 16,Param11; Assem136 = "Vendor Specific 16words control, Drive parameters", , 32, 0x0000, ,, 16,Param11, 16,Param11, 16,Param11, 16,Param11, 16,Param11, 16,Param11, 16,Param11, 16,Param11, 16,Param11, 16,Param11, 16,Param11, 16,Param11, 16,Param11, 16,Param11, 16,Param11, 16,Param11; Assem148 = "Vendor Specific 8words status, Drive parameters", , 16, 0x0000, ,, 16,Param21, 16,Param21, 16,Param21, 16,Param21, 16,Param21, 16,Param21, 16,Param21, 16,Param21; Assem156 = "Vendor Specific 16words status, Drive parameters", , 32, 0x0000, ,, 16,Param21, 16,Param21, 16,Param21, 16,Param21, 16,Param21, 16,Param21, 16,Param21, 16,Param21, 16,Param21, 16,Param21, 16,Param21, 16,Param21, 16,Param21, 16,Param21, 16,Param21, 16,Param21; [Connection Manager] Object_Name = "Connection Manager Object"; Object_Class_Code = 0x06; Connection1 = 0x04010002, $ 0-15 = supported transport classes $ 16 = trigger: cyclic $ 17 = trigger: change of state $ 18 = trigger: application $ 19-23 = trigger: reserved $ 24 = application type: listen-only $ 25 = application type: input-only $ 26 = application type: exclusive-owner $ 27 = application type: redundant-owner $ 28-30 = reserved $ 31 = Direction: Client = 0 / Server = 1 0x44640405, $ 0 = O->T fixed size supported $ 1 = O->T variable size supported $ 2 = T->O fixed size supported $ 3 = T->O variable size supported $ 4-5 = O->T number of bytes per slot (obsolete) $ 6-7 = T->O number of bytes per slot (obsolete) $ 8-10 = O->T Real time transfer format $ 11 = reserved $ 12-14 = T->O Real time transfer format $ 15 = reserved $ 16 = O->T connection type: NULL $ 17 = O->T connection type: MULTICAST $ 18 = O->T connection type: POINT2POINT $ 19 = O->T connection type: reserved $ 20 = T->O connection type: NULL $ 21 = T->O connection type: MULTICAST $ 22 = T->O connection type: POINT2POINT $ 23 = T->O connection type: reserved $ 24 = O->T priority: LOW $ 25 = O->T priority: HIGH $ 26 = O->T priority: SCHEDULED $ 27 = O->T priority: reserved $ 28 = T->O priority: LOW $ 29 = T->O priority: HIGH $ 30 = T->O priority: SCHEDULED $ 31 = T->O priority: reserved ,4,Assem20, $ O->T RPI, size, format ,4,Assem70, $ T->O RPI, size, format ,, $ proxy config size, format ,, $ target config size, format "20/70 Basic speed control(RPM)", $ Connection Name "Instances 20/70, Basic speed control(RPM) assembly", $ help string "20 04 24 01 2C 14 2C 46"; $ Path Connection2 = 0x04010002, $ 0-15 = supported transport classes $ 16 = trigger: cyclic $ 17 = trigger: change of state $ 18 = trigger: application $ 19-23 = trigger: reserved $ 24 = application type: listen-only $ 25 = application type: input-only $ 26 = application type: exclusive-owner $ 27 = application type: redundant-owner $ 28-30 = reserved $ 31 = Direction: Client = 0 / Server = 1 0x44640405, $ 0 = O->T fixed size supported $ 1 = O->T variable size supported $ 2 = T->O fixed size supported $ 3 = T->O variable size supported $ 4-5 = O->T number of bytes per slot (obsolete) $ 6-7 = T->O number of bytes per slot (obsolete) $ 8-10 = O->T Real time transfer format $ 11 = reserved $ 12-14 = T->O Real time transfer format $ 15 = reserved $ 16 = O->T connection type: NULL $ 17 = O->T connection type: MULTICAST $ 18 = O->T connection type: POINT2POINT $ 19 = O->T connection type: reserved $ 20 = T->O connection type: NULL $ 21 = T->O connection type: MULTICAST $ 22 = T->O connection type: POINT2POINT $ 23 = T->O connection type: reserved $ 24 = O->T priority: LOW $ 25 = O->T priority: HIGH $ 26 = O->T priority: SCHEDULED $ 27 = O->T priority: reserved $ 28 = T->O priority: LOW $ 29 = T->O priority: HIGH $ 30 = T->O priority: SCHEDULED $ 31 = T->O priority: reserved ,4,Assem21, $ O->T RPI, size, format ,4,Assem71, $ T->O RPI, size, format ,, $ proxy config size, format ,, $ target config size, format "21/71 Extended speed control(RPM)", $ Connection Name "Instances 21/71, Extended speed control(RPM) assembly", $ help string "20 04 24 01 2C 15 2C 47"; $ Path Connection3 = 0x04010002, $ 0-15 = supported transport classes $ 16 = trigger: cyclic $ 17 = trigger: change of state $ 18 = trigger: application $ 19-23 = trigger: reserved $ 24 = application type: listen-only $ 25 = application type: input-only $ 26 = application type: exclusive-owner $ 27 = application type: redundant-owner $ 28-30 = reserved $ 31 = Direction: Client = 0 / Server = 1 0x44640405, $ 0 = O->T fixed size supported $ 1 = O->T variable size supported $ 2 = T->O fixed size supported $ 3 = T->O variable size supported $ 4-5 = O->T number of bytes per slot (obsolete) $ 6-7 = T->O number of bytes per slot (obsolete) $ 8-10 = O->T Real time transfer format $ 11 = reserved $ 12-14 = T->O Real time transfer format $ 15 = reserved $ 16 = O->T connection type: NULL $ 17 = O->T connection type: MULTICAST $ 18 = O->T connection type: POINT2POINT $ 19 = O->T connection type: reserved $ 20 = T->O connection type: NULL $ 21 = T->O connection type: MULTICAST $ 22 = T->O connection type: POINT2POINT $ 23 = T->O connection type: reserved $ 24 = O->T priority: LOW $ 25 = O->T priority: HIGH $ 26 = O->T priority: SCHEDULED $ 27 = O->T priority: reserved $ 28 = T->O priority: LOW $ 29 = T->O priority: HIGH $ 30 = T->O priority: SCHEDULED $ 31 = T->O priority: reserved ,4,Assem100, $ O->T RPI, size, format ,4,Assem110, $ T->O RPI, size, format ,, $ proxy config size, format ,, $ target config size, format "100/110 Basic speed control(Hz)", $ Connection Name "Instances 100/110, Basic speed control(Hz) assembly", $ help string "20 04 24 01 2C 64 2C 6E"; $ Path Connection4 = 0x04010002, $ 0-15 = supported transport classes $ 16 = trigger: cyclic $ 17 = trigger: change of state $ 18 = trigger: application $ 19-23 = trigger: reserved $ 24 = application type: listen-only $ 25 = application type: input-only $ 26 = application type: exclusive-owner $ 27 = application type: redundant-owner $ 28-30 = reserved $ 31 = Direction: Client = 0 / Server = 1 0x44640405, $ 0 = O->T fixed size supported $ 1 = O->T variable size supported $ 2 = T->O fixed size supported $ 3 = T->O variable size supported $ 4-5 = O->T number of bytes per slot (obsolete) $ 6-7 = T->O number of bytes per slot (obsolete) $ 8-10 = O->T Real time transfer format $ 11 = reserved $ 12-14 = T->O Real time transfer format $ 15 = reserved $ 16 = O->T connection type: NULL $ 17 = O->T connection type: MULTICAST $ 18 = O->T connection type: POINT2POINT $ 19 = O->T connection type: reserved $ 20 = T->O connection type: NULL $ 21 = T->O connection type: MULTICAST $ 22 = T->O connection type: POINT2POINT $ 23 = T->O connection type: reserved $ 24 = O->T priority: LOW $ 25 = O->T priority: HIGH $ 26 = O->T priority: SCHEDULED $ 27 = O->T priority: reserved $ 28 = T->O priority: LOW $ 29 = T->O priority: HIGH $ 30 = T->O priority: SCHEDULED $ 31 = T->O priority: reserved ,4,Assem101, $ O->T RPI, size, format ,4,Assem111, $ T->O RPI, size, format ,, $ proxy config size, format ,, $ target config size, format "101/111 Extended speed control(Hz)", $ Connection Name "Instances 101/111, Extended speed control(Hz) assembly", $ help string "20 04 24 01 2C 65 2C 6F"; $ Path Connection5 = 0x04010002, $ 0-15 = supported transport classes $ 16 = trigger: cyclic $ 17 = trigger: change of state $ 18 = trigger: application $ 19-23 = trigger: reserved $ 24 = application type: listen-only $ 25 = application type: input-only $ 26 = application type: exclusive-owner $ 27 = application type: redundant-owner $ 28-30 = reserved $ 31 = Direction: Client = 0 / Server = 1 0x44640405, $ 0 = O->T fixed size supported $ 1 = O->T variable size supported $ 2 = T->O fixed size supported $ 3 = T->O variable size supported $ 4-5 = O->T number of bytes per slot (obsolete) $ 6-7 = T->O number of bytes per slot (obsolete) $ 8-10 = O->T Real time transfer format $ 11 = reserved $ 12-14 = T->O Real time transfer format $ 15 = reserved $ 16 = O->T connection type: NULL $ 17 = O->T connection type: MULTICAST $ 18 = O->T connection type: POINT2POINT $ 19 = O->T connection type: reserved $ 20 = T->O connection type: NULL $ 21 = T->O connection type: MULTICAST $ 22 = T->O connection type: POINT2POINT $ 23 = T->O connection type: reserved $ 24 = O->T priority: LOW $ 25 = O->T priority: HIGH $ 26 = O->T priority: SCHEDULED $ 27 = O->T priority: reserved $ 28 = T->O priority: LOW $ 29 = T->O priority: HIGH $ 30 = T->O priority: SCHEDULED $ 31 = T->O priority: reserved ,16,Assem128, $ O->T RPI, size, format ,16,Assem148, $ T->O RPI, size, format ,, $ proxy config size, format ,, $ target config size, format "128/148 Vendor Specific 8/8 words, Drive parameters", $ Connection Name "Instances 128/148, Vendor Specific 8/8 words, Drive parameters assembly", $ help string "20 04 24 01 2C 80 2C 94"; $ Path Connection6 = 0x04010002, $ 0-15 = supported transport classes $ 16 = trigger: cyclic $ 17 = trigger: change of state $ 18 = trigger: application $ 19-23 = trigger: reserved $ 24 = application type: listen-only $ 25 = application type: input-only $ 26 = application type: exclusive-owner $ 27 = application type: redundant-owner $ 28-30 = reserved $ 31 = Direction: Client = 0 / Server = 1 0x44640405, $ 0 = O->T fixed size supported $ 1 = O->T variable size supported $ 2 = T->O fixed size supported $ 3 = T->O variable size supported $ 4-5 = O->T number of bytes per slot (obsolete) $ 6-7 = T->O number of bytes per slot (obsolete) $ 8-10 = O->T Real time transfer format $ 11 = reserved $ 12-14 = T->O Real time transfer format $ 15 = reserved $ 16 = O->T connection type: NULL $ 17 = O->T connection type: MULTICAST $ 18 = O->T connection type: POINT2POINT $ 19 = O->T connection type: reserved $ 20 = T->O connection type: NULL $ 21 = T->O connection type: MULTICAST $ 22 = T->O connection type: POINT2POINT $ 23 = T->O connection type: reserved $ 24 = O->T priority: LOW $ 25 = O->T priority: HIGH $ 26 = O->T priority: SCHEDULED $ 27 = O->T priority: reserved $ 28 = T->O priority: LOW $ 29 = T->O priority: HIGH $ 30 = T->O priority: SCHEDULED $ 31 = T->O priority: reserved ,32,Assem136, $ O->T RPI, size, format ,32,Assem156, $ T->O RPI, size, format ,, $ proxy config size, format ,, $ target config size, format "136/156 Vendor Specific 16/16 words, Drive parameters", $ Connection Name "Instances 136/156, Vendor Specific 16/16 words, Drive parameters assembly", $ help string "20 04 24 01 2C 88 2C 9C"; $ Path Connection7 = 0x04010002, $ trigger & transport $ 0-15 = supported transport classes (class 1) $ 16 = cyclic (1 = supported) $ 17 = change of state (0 = not supported) $ 18 = on demand (0 = not supported) $ 19-23 = reserved (must be zero) $ 24-27 = exclusive owner $ 28-30 = reserved (must be zero) $ 31 = client 0 (don't care for classes 0 and 1) 0x44640405, $ point/multicast & priority & realtime format $ 0 = O=>T fixed (1 = supported) $ 1 = O=>T variable (0 = not supported) $ 2 = T=>O fixed (1 = supported) $ 3 = T=>O variable (0 = not supported) $ 4-7 = reserved (must be zero) $ 8-10 = O=>T header (4 byte run/idle) $ 11 = reserved (must be zero) $ 12-14 = T=>O header $ 15 = reserved (must be zero) $ 16-19 = O=>T point-to-point $ 20-23 = T=>O multicast $ 24-27 = O=>T scheduled $ 28-31 = T=>O scheduled ,Param1,Assem1, $ O=>T RPI,Size,Format ,Param2,Assem2, $ T=>O RPI,Size,Format ,, $ config part 1 (dynamic assemblies) ,, $ config part 2 (module configuration) "IO Connection", $ connection name "", $ Help string "20 04 24 01 2C [Param3] 2C [Param4]"; $ exclusive output path [Port] Object_Name = "Port Object"; Object_Class_Code = 0xF4; Port1 = TCP, $ port type name "EtherNet/IP", $ name of port "20 F5 24 01", $ instance one of the TCP/IP interface object 2, $ port number 0, ;